| EPD Plug Part Number Code Logic | |||||
| EPD | - | 3 | 30 | 3 | 2 |
| 1 | 2 | 3 | 4 | 5 | |
| 1 | Classification | EPD = Explosion proof Class I, Groups C & D
|
![]() |
||
| 2 | Cable Diameter Range | 3 5 7 |
= |
.250" to .625" (15 Amp)
|
|
| 3 | Rating | 15 15 30
|
= = =
|
20 amps / 1" HP 20 amps / 1½" HP 30 amps / 1½" HP 30 amps / 3 HP
|
2 Pole, 3 Wire at 120 or 240 Vac 3 Pole, 4 Wire at 120 or 240 Vac 2 Pole, 3 wire at 120 or 240 Vac 3 Pole, 4 Wire at 120 or 240 Vac |
| 4 | Insert | 3 4 |
= = |
2 pole, 3 wire
|
|
| 5 | Voltage | 2 |
= |
240 volts. See rating specified above. |
|